The barrier is made of pe material which is strong enough for daily use, equiped with the wheels it can be moved easily, with the hinges it can be folded or connected as long as you want.
Bright yellow catches more attention, the customized logo and warning words can be wonderful advertisement for your company
Two heights for your decision, 760mm and 1018mm
Supplier: Borosilicate 4.0 fire resistant glass:
the maximum fire resistance time is 3 hours, ultra low expansion coefficient
small specific gravity, more than 8% lighter than ordinary soda lime silica glass ultra clear, light transmittance above 92%
thickness range: 4 15mm maximum size: 4800*2440mm
can be used in fireproof curtain walls, partition walls, platforms, day lighting roofs, smoke proof vertical walls, railings, doors and windows, elevator shafts, rail transit platform screen doors, rail locomotive doors and windows and other fields.
Buyer: High purity quartz lump with sio2 99.8%+ for crucibles, borax pentahydrate, mica quartz
1, let students familiar with the industrial commonly used sidewalk escalators working principle, structure composition, low-voltage electrical structure and principles. 2, through the analysis of electrical schematics, students with the help of schematic analysis, master the safety protection and working form of elevators, and through analysis and measurement, to find out the location of fault points, a deep understanding of the operation of elevators. 3, improve the actual hands-on analysis ability of students, and actually improve the level of skill operation. 4, through the analysis and elimination of elevator faults, to complete the common elevator fault cognition and understanding. 5, through the PLC host programming, understand the PLC program programming principles and methods. 6, escalator safety operation and use of practical training 7, rung disassembly operation and practical training 8, comb plate adjustment and practical training 9, armrest belt tension adjustment and practical training 10, rung chain tension adjustment and practical training 11, brake adjustment and practical training 12, maintenance before the safety knowledge operation and practical training Daily maintenance 13, escalator emergency rescue 14, escalator safety circuit fault finding and troubleshooting practical training 15, escalator access circuit fault finding and troubleshooting training 16, escalator safety monitoring circuit fault finding and troubleshooting training 17, escalator power circuit fault finding and troubleshooting practical training 18, escalator control circuit fault finding and troubleshooting training
1, sensor detection 2, the basic use of the drive 3, timer instructions 4, mathematical instructions 5, high-speed counter 6, car automatic switch door control 7, elevator simulation run call indication driver 8, floor display 9, door machine torque safety protection 10, hall door security control 11, elevator terminal switch protection 12, elevator lift deceleration control 13, the use of photoelectric encoder positioning
Super quality folding retractable safety barriers from china expandable road safety barrier Customers can adjust the working length freely according to the actual demand. Products are especially suitable for temporary construction, equipment maintenance, emergency the scene of the accident isolation and other places. Name expandable barrier Material pvc Surface Color bright yellow Oem printing Expanding demension 1100mm*3600mm Features Flexible, lightweight barrier in concertina design. Easy to transport and store
The barrier is made of pe material which is strong enough for daily use, equiped with the wheels it can be moved easily, with the hinges it can be folded or connected as long as you want. Bright yellow catches more attention, the customized logo and warning words can be wonderful advertisement for your company Two heights for your decision, 760mm and 1018mm
Accurate perception of the seismic information Avoid earthquake damage to the elevator Timely rescue of trapped person Participate in the State administration of quality supervision the 2008QK21 subject research Participate in the National elevator shockproof standards drafting SYSTEM OVERVIEW The elevator earthquake detector is used in conjunction with the elevator control system, make the elevator before the earthquake happened or occurs effective enter into the control operation of the equipment. Before the earthquake arrival, the elevator earthquake detector early detection to seismic waves, output alarm contacts to the elevator control system, the elevator control system according to the contacts state in the recent floor flat layer to open the door, release the passengers out of the elevator, the maximum save the life safety of the passengers, ensure that the elevator equipment is not compromised. FEATURES AND PARAMETERS Input voltage:AC220 10% 50 Hz 60 Hz Output way:2 relay output Contacts capacity:1.0 A 30 V DC, 0.5 A 125 V AC Frequency response:0.1 Hz 30 Hz Level 1 alarm acceleration threshold set range:0.2 m/s 1m/s Level 2 alarm acceleration threshold set range:0.4 m/s Acquisition accuracy:0.01m/s Reset way:manual reset Alarm record:100 strips Overall Power Consumption: 1 W Weight:1kg SYSTEM PRINCIPLE Product collection when the earthquake ground X/Y/Z three of the direction of ground motion acceleration, accurate detection of the earthquake happened, when P wave arrived acceleration sensor detected early earthquake of vertical vibration then output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed. When S wave arrival, acceleration sensors to detect the horizontal vibration, and output corresponding electric signals, through the filter and amplification by Analog to Digital Converter for microprocessor processed. The instrument has two road relay output, respectively is level 1 alarm output, level 2 alarm output, access the elevator control system respectively, for the elevator control system collection. Level 1 alarm output is instruments detected early earthquake P wave or low vibration acceleration of earthquake movement after output, is a low-level output, used to judge may be happen earthquake, after Level 1 alarm relay action, if in 10s inside not have to achieve the Level 2 alarm ground vibration signal, the product to be automatic reset, and contacts signals disappear. Level 2 alarm output corresponding higher ground motion of the output of the acceleration, can't automatic reset, and need professional elevator operator to inspection elevator, and after confirm the elevator without any fault then manually reset. FUNCTION CHARACTERISTICS
BC100 traction drive elevator brake capability detector is a kind of equipment to detect if the traction elevator braking capacity is qualified .
Elevator.
Elevators and escalators Sales, installation, maintenance and modernization diffrent type of elevatirs and escalators. (passenger, freight, residential, service, bed and observation). Standard of manufacturer company .